<LOGO>
FM Transmitter Measurement Report
Created: 2026-04-06 06-00-30
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 5/5, 65 dBuV SelectUK
Pilot RDS Phase Difference
6.6 kHz 4.2 kHz 73 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 70 kHz 19150 0,5587
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,2 dBr 5,14 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SelectUK" C46F 15 (Other M) 1 0 1 5 5:00, 6.04.2026
RT
" ec Mond "
AF EON
94.4, 99.3, 105.7 MHz -
FM Scope Max at: 70 kHz MIN: 17 kHz % above 76 kHz: 0,5587 Acquired: 2026/04/06 5.59.25 Total samples: 19150 Equivalent time: 0:15:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500 2000
FM Scope MAX: 5,7 dBr MIN: 4,2 dBr AVE: 5,14 dBr % above 12,2 dBr: 0,0 Last value: 5,2 dBr (2026/04/06 5.59.25) 05.46 05.48 05.50 05.52 05.54 05.56 05.58 0 2 4 6 Pm [dBr]